SIGNAL BOOSTER ENGINEERING:
COMMON COAXIAL CABLE LOSS APPROXIMATION CHART

The following information is based on specifications published in recent manufacturers specification sheets that are distributed publicly and subject to change without notice.

Notations: "CC" = Corrugated Copper cable. "TA" = Trilogy Communications cable.
"STD" = Standard, non-radiating type. "RAD" = Radiating ("Leaky") type cable.

Loss is stated in dB/100 (decibels per 100 feet of cable).
"RAD Cpl" = Radiating Cable "Coupling Loss" in dB, 20 feet from cable.(nominal)


50 MHz
----------
STD dB/100
RAD dB/100
RAD Cpl
Type
TA 1/2"
0.55
0.68
64
Type
CC 1/2"
0.46
0.41
60
Type
TA 3/4"
0.39
0.48
65
Type
CC 7/8"
0.35
0.4
63
Type
TA 7/8"
0.27
0.34
67
Type
CC 1.25"
0.2
0.24
64
150 MHz
----------
STD dB/100
RAD dB/100
RAD Cpl
Type
TA 1/2"
0.91
1.14
65
Type
CC 1/2"
0.845
0.94
58
Type
TA 3/4"
0.64
0.8
68
Type
CC 7/8"
0.458
0.54
58
Type
TA 7/8"
0.48
0.6
68
Type
CC 1.25"
0.34
0.39
59
250 MHz
----------
STD dB/100
RAD dB/100
RAD Cpl
Type
TA 1/2"
1.14
1.39
66
Type
CC 1/2"
1.02
1.5
61
Type
TA 3/4"
0.81
1.01
66
Type
CC 7/8"
0.63
0.75
60
Type
TA 7/8"
0.6
0.75
66
Type
CC 1.25"
0.44
0.55
63
450 MHz
----------
STD dB/100
RAD dB/100
RAD Cpl
Type
TA 1/2"
1.61
2.01
65
Type
CC 1/2"
1.51
2.1
63
Type
TA 3/4"
1.11
1.4
63
Type
CC 7/8"
0.834
1.1
63
Type
TA 7/8"
0.85
1.08
63
Type
CC 1.25"
0.617
0.80
66
850 MHz
----------
STD dB/100
RAD dB/100
RAD Cpl
Type
TA 1/2"
2.29
2.81
67
Type
CC 1/2"
2.15
3.0
67
Type
TA 3/4"
1.56
1.9
66
Type
CC 7/8"
1.2
1.8
69
Type
TA 7/8"
1.21
1.52
69
Type
CC 1.25"
0.89
1.2
71
1.0 GHz
----------
STD dB/100
RAD dB/100
RAD Cpl
Type
TA 1/2"
2.47
3.08
68
Type
CC 1/2"
2.4
4.5
69
Type
TA 3/4"
1.69
2.11
69
Type
CC 7/8"
1.3
2.95
70
Type
TA 7/8"
1.33
1.68
69
Type
CC 1.25"
1.0
1.1
70

(c) 2005 Jack Daniel Company.
Last Update: September 11, 2005

Send Us Your Comments, Additions and Corrections